Inline Filters
6090 psi • up to 200 gpm
Features
Technical Specifications
Mounting Method | 4 mounting holes | ||
Port Connection |
|
||
Flow Direction | Inlet: Side Outlet: Side |
||
Construction Materials |
|
||
Flow Capacity |
|
||
Housing Pressure Rating |
Max. Allowable Working Pressure 6090 psi (420 bar) Fatigue Pressure 6090 psi (420 bar) @ 1 million cycles Burst Pressure
|
||
Element Collapse Pressure Rating | BH4HC, V 3045 psid (210 bar) ON, W/HC 290 psid (20 bar) |
||
Fluid Temp. Range | 14°F to 212°F (-10°C to 100°C) | ||
Fluid Compatibility | Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected. |
||
Indicator Trip Pressure | ∆P = 29 psid (2 bar) -10% (optional) ∆P = 72 psid (5 bar) -10% (standard) ∆P = 116 psid (8 bar) -10% (optional non bypass) |
||
Bypass Valve Cracking Pressure | ∆P = 43 psid (3 bar) +10% (optional) ∆P = 87 psid (6 bar) +10% (standard) Non Bypass Available |