Mounting Method | 4 mounting holes |
Port Connection | 30 60/110 160/240/280 330/660/1320 | SAE-8, 1/2” NPT, 1/2” BSPP SAE-12, 3/4” NPT, 3/4” BSPP 3/4” SAE, Code 62 SAE-20, 1 1/4” NPT, 1 1/4” BSPP 1 1/4” SAE, Code 62 SAE-24, 1 1/2” NPT, 1 1/2” BSPP 2” SAE Flange Code 62 |
|
Flow Direction | Inlet: Side Outlet: Side |
Construction Materials | Head Bowl (30-660) Housing/Bowl (660-1320 - 2.0) Cap/Lid (660-1320 type) | Ductile iron Steel Steel Steel |
|
Flow Capacity | 30 60 110 160 240 280 330 660 1320 | 8 gpm (30 lpm) 16 gpm (60 lpm) 29 gpm (110 lpm) 42 gpm (160 lpm) 63 gpm (240 lpm) 74 gpm (280 lpm) 87 gpm (330 lpm) 174 gpm (660 lpm) 200 gpm (757 lpm) |
|
Housing Pressure Rating | Max. Allowable Working Pressure 6090 psi (420 bar) Fatigue Pressure 6090 psi (420 bar) @ 1 million cycles Burst Pressure 30 60/110 160/240/280 330/660/1320 | 15950 psi (1100 bar) 17400 psi (1200 bar) 17110 psi (1180 bar) 15080 psi (1040 bar) |
|
Element Collapse Pressure Rating | BH4HC, V 3045 psid (210 bar) ON, W/HC 290 psid (20 bar) |
Fluid Temp. Range | 14°F to 212°F (-10°C to 100°C) |
Fluid Compatibility | Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected. |
Indicator Trip Pressure | ∆P = 29 psid (2 bar) -10% (optional) ∆P = 72 psid (5 bar) -10% (standard) ∆P = 116 psid (8 bar) -10% (optional non bypass) |
Bypass Valve Cracking Pressure | ∆P = 43 psid (3 bar) +10% (optional) ∆P = 87 psid (6 bar) +10% (standard) Non Bypass Available |