HY-TTC 71 is a powerful electronic control solution for off highway industries with 12V power supply. Due to the highly optimized ratio between number of I/O's and the size of the controller, it can be mounted on machines with very little space. Its compact, automotive-style housing withstands extreme conditions such as humidity, vibrations, temperature changes and mechanical load.
Features
All I/O's and interfaces mentioned below are protected against short circuit to GND and BAT+.
CPU Core
- 16/32-bit Infineon XC2288 safety microcontroller, 80 MHz, 1.6 MB int. Flash, 138kB int. RAM
- 32kB ext. EEPROM
Interfaces
- 1 x CAN, 125 kbit/s up to 1 Mbit/s Optional CAN termination via 2 connector pins
Outputs
- 6 x digital OUT, up to 2,5 A, high side with freewheeling diode for higher inductive loads
- 12 x digital OUT, up to 2,5 A, high side for individual outputs
Inputs
- 10 x analog IN, 0 to 15V Pull-Up in digital IN mode
- 10 x analog IN, 0 to 15V Pull-Down in digital IN mode
- 1 x digital timer IN (0.1 Hz to 10kHz) low side, with voltage measurement
- 2 x analog IN, 0 to 5 V
- 1 x analog IN, configurable in software
0 - 5V 0 - 25 mA
0 - 65 kOhm digital IN low side - 1 x analog IN, 0 – 25 mA
Other
- Internal: monitoring of board temperature, sensor supply and battery
- 1 x sensor supply 5V, 100mA
- 3 x analog sensor ground
- 1 x digital sensor ground
Software
Specifications
Parameter |
ECU Dimensions | 143,13 x 216,32 x 42,77 mm |
Dimensions for Minimum Connector Release Clearance | 197,7 x 216,32 x 42,77 mm |
Weight | 590 g |
Operating Temperature | - 40 to +85 °C (full load) - 40 to +105 °C (lim. load) |
Operating Altitude | 0 to 4000 m |
Supply Voltage | 7 to 16 V |
Peak Supply Voltage | 28 Vmax |
Max Idle Current | 0.15 Amax at 9V |
Standby Current | 0.5 mA |
Total Load Current | 35 Amax |
Standards |
CE-Mark | 2014/30/EU |
E- Mark | ECE-R10 Rev.4 |
EMC | EN 13309 ISO 14982 CISPR 25 |
ESD | ISO 10605 |
Electrical | ISO 16750-2 Starting profile, Level II (4,5 V), functional status A ISO 7637-2,-3 |
Ingress Protection | EN 60529 IP67 ISO 20653 IP6k9k |
Climatic | ISO 16750-4 |
Mechanical | ISO 16750-3 |
Housing and Connector
- Aluminum pressure die-cast housing
- Water-proof 80-pin connector
- Pressure adjusting with water barrier