The CAN Temperature Sensor-PPC-CAN-T are specially designed for use with the CAN Hydraulic Testers. This sensor is using the CANopen protocol to transfer the measurement values to the CAN Hydraulic Testers. The Sensor-PPC-CAN-T is compatible with the CAN Flow Turbine Flow-meter-PPC-CANSFM and the Straight Threaded Joint SGV-16S-G-W3. Most technical details are the same as with the Temperature Sensor-PPC-04/12-T.
Due their sturdy Stainless Steel design with automatic sensor recognition, the CAN Temperature Sensor is a reliable and flexible solution for the CAN Hydraulic Tester. The status of the sensor is indicated via LED. Connecting the CAN Temperature Sensor to the CAN Hydraulic Tester a CAN Connection Cable and a CAN Terminating Resistor is needed.
Technical Data
Suitable for liquids
5-pin SPEEDCON connection plug
Sensor identification LED
Materials
Housing (T): Stainless Steel
Gaskets (T): FKM (Viton®)
Weight
M02 (M10x1): 70 g (.15 lbs)
B04 (G1/4): 55 g (.12 lbs)
Ambient Conditions (Screw-in Temperature Sensor)
Media temperature: -40°C to+150°C (-40°F to +302°F)
Ambient temperature: -40°C to +85°C (-40°F to +185°F)
Storage temperature: -40°C to +85°C (-40°F to +185°F)
Ambient Conditions (Rod-type Temperature Sensor)
Media temperature: -25°C to +125°C (-13°F to +257°F)
Ambient temperature: -25°C to +70°C (-13°F to +158°F)
Storage temperature: -25°C to +80°C (-13°F to +176°F)
Measuring Range
Measuring range: -40°C to +150°C (-40°F to +302°F)
Operating pressure: 630 bar (9137 PSI)
Maximum pressure: 800 bar (11603 PSI)
Burst pressure: 2150 bar (31183 PSI)
Accuracy: ±0,66 % FS
CANopen Interface
CANopen protocol profile DS301, Typ 2.0A with manufacturer-specific additions
LSS service DS305 v2.0
Electrical Data
Output signal: CAN bus
Response time M02 (M10x1): T50 ≤ 4 s, T90 ≤ 12 s B04 (G1/4): T50 ≤ 4 s, T90 ≤ 14 s